Not Available in Your Country
Sorry, this page is not
available in your country.
Overview
Total internal reflection fluorescence (TIRF) microscopy has become firmly established over the last few years as a key technique in the investigation of molecular interactions at or near the cell surface. Olympus is experienced in providing advanced TIRF solutions and cellTIRF family takes this technology to the next level with a series of peerless features such as highly advanced optics, unique independent laser control and exceptional accuracy. The cellTIRF-4Line system is easy to use for TIRF, single molecule localization microscopy and FRAP for a range of experimental protocols. |
Principles of TIRF MicroscopyTraditional widefield microscopes illuminate the entire depth of a sample. Total Internal Reflection Fluorescence (TIRF) microscopy is used to acquire images of a very thin section with high resolution. This is done through the use of a laser beam that is precisely positioned in the objectives back focal plane. Doing so creates an angle ideal for total internal reflection of the laser beam so that it can also be collected by the objective lens. Therefore, the laser beam never actually transmits through a sample during TIRF, and instead only a small area within roughly 200 nm of the coverslip is illuminated by an evanescent field. This evanescent field is caused by a difference in refractive indices between the sample and the glass coverslip on which it sits, and is responsible for the high signal-to-noise ratio of TIRF images. |
True Multicolor TIRF with Independent Angle ControlOlympus cellTIRF-4Line system enables ultra-sensitive, simultaneous multicolor TIRF using four laser channels with independent beam paths. Individual motorized angle control for each laser ensures equal evanescent penetration (±1 nm), which enables the user to produce high-contrast images with minimal background noise for cell surface and single molecule studies. Since the angle of each laser source is independently motorized, their penetration depths can be synchronized across each wavelength using cellSens software. This also provides key data about the penetration depths that are possible with each laser/objective pair. |
---|
Ease of UseSwitching between widefield burner, widefield laser illumination, critical angle or even two different preset penetration depths, is as simple as pushing a single button. The Experiment Manager also enables the penetration depth to be changed during the course of an experiment. |
The Advanced TIRF Objective FamilyOlympus offers four dedicated TIRF objectives with exceptional optical quality. The 100x objective, with an NA of 1.7, provides the highest resolution currently available. For greater magnification, a 150x (1.45 NA) objective is also available. These advanced TIRF objectives allow investigation to now be made with single molecule precision. New 100x and 60x objectives offer an increased NA of 1.49 to ensure exact angle control and shorter penetration depth - a great advantage for cell membrane studies. |
---|
Broad Range of cell* LasersThe cell* laser family consists of 11 compact, silent and long-life diode and DPSS lasers from 405 to 640nm, with laser power of up to 300 mW. The lasers are self-configured in the Olympus cellSens software using the intelligent ODB (Olympus Digital Bus) connection. Shuttering and attenuation can be performed in real-time using the Experiment Manager. |
HILO Microscopy for Light-sensitive ApplicationsThe cellTIRF-4Line system provides the ideal optical settings for advanced HILO (highly inclined laminated optical sheet) microscopy. By using a highly inclined, thin light beam, image intensity is increased and background intensity decreased, yielding a signal-to-background ratio about eight times greater than that of epi-illumination. HILO microscopy is especially useful for observing light-sensitive, living tissue and for performing time-lapse studies. |
---|
Point FRAPOlympus cellTIRF-4Line system has integrated point FRAP optics for the first laser line. This enables FRAP and photo-switching experiments without additional cost. Turning a button on the TIRF illuminator switches the light from one laser into a refraction-limited spot, allowing photomanipulation. The sample can then be imaged using the remaining TIRF lasers or through widefield microscopy. The real-time controller offers a switching time of 100 microseconds and outstanding data quality for these protocols. |
Need assistance? |
Specifications
Available Laser Systems | |
---|---|
405 nm 60 mW | Diode laser system with direct control of light output via software, incl. optical fiber, optimized for 405 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
405 nm 100 mW | Diode laser system with direct control of light output via software, incl. optical fiber, optimized for 405 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
445 nm 50 mW | Diode laser system with direct control of light output via software, incl. optical fiber, optimized for 445 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
473 nm 100 mW | Diode laser system with direct control of light output via software, incl. optical fiber, optimized for 473 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
488 nm 60 mW | Diode laser system with direct control of light output via software, incl. optical fiber, optimized for 488 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
488 nm 100 mW | Diode laser system with direct control of light output via software, incl. optical fiber, optimized for 488 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
488 nm 200 mW | Diode laser system with direct control of light output via software, incl. optical fiber, optimized for 488 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
488 nm 150 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 488 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
491 nm 50 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 491 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
491 nm 100 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 491 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
491 nm 200 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 491 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
514 nm 50 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 514 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
515 nm 80 mW | Diode laser system with direct control of light output via software, incl. optical fiber, optimized for 515 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
532 nm 100 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 532 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
532 nm 300 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 532 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
561 nm 50 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 561 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
561 nm 100 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 561 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
561 nm 150 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 561 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
561 nm 300 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 561 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
594 nm 50 mW | Solid state laser system with direct control of light output via software, incl. optical fiber, optimized for 594 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
640 nm 100 mW | Diode laser system with direct control of light output via software, incl. optical fiber, optimized for 640 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
640 nm 140 mW | Diode laser system with direct control of light output via software, incl. optical fiber, optimized for 640 nm, polarization maintaining, length 3 m with laser coupling via 4-axis fiber manipulator. |
Applications
Actin Polymerization | FoLu EGFP Vinculin |
FoLu Cells mEmerald AlphaActinin mCherry LifeAct | FoLu mEmerald LifeAct mCherry Zyxin |
FoLu mEmerald Tubulin mApple Zyxin 60xcc | LLC-PK1 mEGFP Cadherin mApple Cadherin 100x |
LLC-PK1 mEGFP Cadherin mApple Cadherin 100x | LLC-PK1 mEGFP Cx26 mApple Cadherin 100x |