The FV1200MPE laser sharing system setup allows two microscopes to share a single IR laser. Both microscopes can be used independently, and the user is able to guide the IR laser to any of the frames, or to split it to both. The motorized beam-expander achieves auto-adjustment of the beam diameter in accordance with the objective and excitation wavelength in order to provide optimal conditions for multiphoton microscopy.
Not Available in Your Country
Sorry, this page is not
available in your country.
This system allows two microscopes to share a single laser and provides cutting-edge technology for various areas of scientific research such as neuroscience and cell biology. In this way, the FV1200MPE system types M, B, S and T can be combined on a single platform.
Anti-oxidization silver coating ensures durability and improves reflection efficiency in both excitation and emission with the set of two galvanometer scanning mirrors, increasing the reflectance in the visible range by 5 - 15 %, and IR reflectance up to 22 %, improving multiphoton excitation efficiency by nearly 50 % at depth.
As the probability for multiphoton excitation is very low, it is crucial to have a very small excitation volume (requiring objectives with high NA) and to guide as much IR light to the sample as possible. This means the rear opening (backfocal aperture) of the objective should be filled completely by the excitation laser beam. Having the beam larger than the backfocal aperture would mean loss of excitation laser light. The backfocal apertures of objectives sometimes differ by more than a factor of two, leading either to losses or to reduced NA. By implementing motorized beam expander optics, Olympus ensures that for all the objectives and different wavelengths used, the size of the IR beam is right for the backfocal aperture of the objective.
The integrated AOM module enables high-speed control of the laser, both for switching on/off and for adjusting intensity.
In multiphoton microscopy, a pulsed laser is required to achieve sufficient excitation efficiency of the fluorophores. As laser pulses (typically ~ 100 fs) are stretched when travelling through microscope optics (dispersion), fluorophore excitation and fluorescence detection will become less efficient. By using a femtosecond-pulsed laser with pulse pre-compensation (negative chirp), this effect can be strongly reduced and the original pulse-width almost completely restored. For specifications please see the FV1000MPE M, B, S, and T-System component pages.