Not Available in Your Country
Sorry, this page is not
available in your country.
Overview
Fully Motorized and Easy to UseFlexible and easy to use, the fully motorized BX63 microscope uses the motorized nosepiece to focus onto the sample, enabling the stage to be fixed for added stability. The smooth, silent motorized stage is driven by ultrasonic piezo technology for precise operation. |
Fast, Efficient Image CaptureEnter observation condition data in the touch panel controller, and it’s automatically transferred to cellSens image analysis software. The process manager enables fully automated multichannel image acquisition. |
---|
Control at Your FingertipsThe controller enables you to change observation methods with just a touch. Choose between guidance mode to navigate the procedures currently in use and full mode for access to the entire range of settings. You can save multiple observation points and conditions in advance and quickly recall previously used imaging conditions. |
---|
Familiar Focusing and XY Stage ControlsYou can detach the stage controller from the frame and place it where it’s most convenient. When used with the ultrasonic stage, it creates a user-friendly workflow with an operation that mimics a manual focusing stage. Switches on the controller enable you to change between different observation methods, objectives, and mirror units while simultaneously selecting intensity adjustments or image capture. |
---|
Need assistance? |
Applied Technologies
Stable ImagingThe fixed stage facilitates stable, reliable imaging. Samples are focused using the precise motorized nosepiece. Z-stack capture and deconvolution are also highly accurate. |
---|
Efficient Motorized Nosepiece and Field DiaphragmChange objectives using either the remote handset or PC software for efficient imaging. When combined with cellSens software, you can automate advanced imaging techniques that require multiple magnifications. |
---|
Even Fluorescence Across the Field of ViewFluorescence illuminators with a fly-eye lens provide homogenous illumination across the entire wavelength spectrum and simplify burner alignment. | Surface of Fly-eye Lens System, Enlarged Image |
---|
Flexible 8-Position IlluminatorEasily changeable mirror units to provide flexibility for a wide variety of fluorescence specimens. The design reduces the need to replace mirror units for multicolor or FISH applications, further accelerating your work. |
---|
Mirror Units Optimized for FluorescenceThe fluorescence mirror units have advanced coatings that provide high transmission and steep cut-off slopes. The interior surfaces eliminate over 99% of stray light for high sensitivity and sharp color separation. |
High-Transmission Objectives with Reduced AutofluorescenceUIS2 objectives with a high numerical aperture (NA) have chromatic aberration corrections to provide high resolution, even from faint fluorescence signals. Advanced coating technologies reduce autofluorescence and improve the signal-to-noise ratio for flat, high transmission over a wide wavelength. |
---|
Need assistance? |
Specifications
Observation Method > Brightfield | ✓ | |
---|---|---|
Observation Method > Darkfield | ✓ | |
Observation Method > Phase Contrast | ✓ | |
Observation Method > Fluorescence (Blue/Green Excitations) | ✓ | |
Observation Method > Fluorescence (Ultraviolet Excitations) | ✓ | |
Observation Method > Differential Interference Contrast | ✓ | |
Observation Method > Simple Polarized Light | ✓ | |
Illuminator > Transmitted Köhler Illuminator > LED Lamp | ✓ | |
Illuminator > Transmitted Köhler Illuminator > 100 W Halogen Lamp | ✓ | |
Illuminator > Fluorescence Illuminator > 100 W Mercury Lamp | ✓ | |
Illuminator > Fluorescence Illuminator > Light Guide Illumination | ✓ | |
Focus > Focusing Mechanism > Nosepiece Focus | ✓ | |
Focus > Motorized |
| |
Intermediate Magnification Changer > Manual Terret | ✓ | |
Revolving Nosepiece > Motorized (7 positions) | ✓ | |
Stage > Motorized | Contact your local sales representative to hear about motorized stage options | |
Stage > Manual > Manual Stages with Right-Hand Control |
| |
Stage > Mechanical > Oil Rectangular Stage with Right-Hand Control |
| |
Condenser > Motorized > Universal Condenser | NA 0.9/ W.D. 1.5 mm for 1.25X–100X [swing-out: 1.25X–4X, with oil top lens: (NA 1.4/ W.D. 0.63 mm)] | |
Condenser > Manual > Universal Condenser | NA 0.9/ W.D. 1.5 mm for 1.25X–100X [swing-out: 1.25X–4X, with oil top lens: (NA 1.4/ W.D. 0.63 mm)] | |
Condenser > Manual > Swing-Out Condenser | NA 0.9/ W.D. 2 mm (1.25X–100X) | |
Condenser > Manual > Achromatic/Aplanatic Condenser | NA 1.4/ W.D. 0.7 mm (oil) (10X–100X) | |
Condenser > Manual > Darkfield Condenser Dry | NA 0.8–0.92/ W.D. 4.52 mm (10X–40X) | |
Condenser > Manual > Darkfield Condenser Oil | NA 1.2–1.4/ W.D. 0.5 mm (20X–100X) | |
Observation Tubes > Widefield (FN 22) > Binocular | ✓ | |
Observation Tubes > Widefield (FN 22) > Tilting Binocular | ✓ | |
Observation Tubes > Widefield (FN 22) > Trinocular | ✓ | |
Observation Tubes > Widefield (FN 22) > Tilting Trinocular | ✓ | |
Observation Tubes > Widefield (FN 22) > Ergonomic Tilting Binocular | ✓ | |
Observation Tubes > Widefield (FN 22) > Tilting, Telescopic, Lifting Binocular | ✓ | |
Observation Tubes > Widefield (FN 22) > Trinocular for Infrared | ✓ | |
Observation Tubes > Widefield (FN 22) > Erected Trinocular | ✓ | |
Observation Tubes > Widefield (FN 22) > Erected Ergonomic Tilting Binocular | ✓ | |
Dimensions (W × D × H) | 294.5 mm × 740.5 mm × 582.5 mm (12 in. × 29.2 in. × 23 in.) (Epifluorescence configuration) | |
Weight | 35 kg (Epifluorescence Configuration) | |
Operating Environment > Indoor Use > Ambient Temperature | 5 °C–40 °C (41 °F–104 °F) | |
Operating Environment > Indoor Use > Maximum Relative Humidity | 80% for temperatures up to 31 ºC (88 ºF), decreasing linearly through 70% at 34 ºC (93 ºF), 60% at 37 ºC (99 ºF), to 50% relative humidity at 40 ºC (104 ºF) | |
Operating Environment > Indoor Use > Supply Voltage Fluctuations | ±10 % |